flWorkFWCtrlAutoUpdate
flWorkFWCtrlConf
OID 1.3.6.1.4.1.4346.11.11.11.2.5
flWorkFWCtrlConfStatus
flWorkFWCtrlConfSave
flWorkFWCtrlDefaultUponDelivery
flWorkFWCtrlSerial
OID 1.3.6.1.4.1.4346.11.11.11.2.6
OID 1.3.6.1.4.1.4346.11.11.11.2.4.7
Syntax Integer
Access Read/write
Description This object can be used to trigger the firmware update with subsequent restart:
No firmware update 1
Execute firmware update 2
OID 1.3.6.1.4.1.4346.11.11.11.2.5.1
Syntax Integer
Access Read
Description This object can be used to request the status of the active device configuration:
Configuration OK 1
Configuration faulty 2
Configuration saved 3
Saving configuration 4
OID 1.3.6.1.4.1.4346.11.11.11.2.5.2
Syntax Integer
Access Read/write
Description This object can be used to save the device configuration:
Do not save configuration 1
Save configuration 2
OID 1.3.6.1.4.1.4346.11.11.11.2.5.3
Syntax Integer
Access Read/write
Description This object can be used to set the device to the default settings (basic settings - see 2.1.1 on
page 2-1). It also triggers a restart:
Do not reset to default settings 1
Reset to default settings 2