61
5277A
Display Description Remedy
0CC0 to
0CC3
0DC0 to
0DC3
Multiple error at the branching bus interface (OUT2) of the specified
device. An INTERBUS cable is connected without any further de-
vices, defective device in the local bus connected or failure of the
communication voltage V
L
.
Check the local bus.
0CC4 to
0CC7
0DC4 to
0DC7
Multiple timeout at the branching bus interface (OUT2) of the spec-
ified INTERBUS device due to a defective device, defective local
bus cable or failure of the logic voltage V
L
.
0CC8 to
0CCB
0DC8 to
0DCB
Other unexpected devices were found at the branching bus interface (OUT2) of the specified device. Device connect-
ed without an entry in the active configuration or INTERBUS cable without connected devices.
0CCC to
0CCF
0DCC to
0DCF
Only ID cycles but no data cycles can be run. Replace the device or adapt the length code in
the configuration frame.