The slave chip of the specified INTERBUS device is a SUPI1 which
is operated in the µP mode. This mode is not supported by the firm-
ware.
Please contact Phoenix Contact.
0C58
to 0C5B
0D58
to 0D5B
The data transmission was aborted at the outgoing remote bus interface (OUT1) of the specified device.
0C5C
to 0C5F
0D5C
to 0D5F
The data transmission was aborted at the branching bus interface (OUT2) of the specified device.
0C60
to 0C63
0D60
to 0D63
Transmission error at OUT1. The SUPI3 detected a CRC or MAU
(Medium Attachment Unit) error.
Replace the INTERBUS device and contact
Phoenix Contact.