Page #4 background imageLoading...
Page #4 background image
PDP-507XD
4
1234
1234
C
D
F
A
B
E
Fig.1 High Voltage Generating Point (Rear view)
The places where voltage is 100 V or more except for the charged
places described above. If the places are touched, there is a risk of
electric shock.
The VSUS voltage remains for several minutes after the power to
the unit is turned off. These places must not be touched until
about 10 minutes after the power is turned off, or it is confirmed
with a tester that there is no residual VSUS voltage.
If the procedures described in “10.3 POWER ON/OFF FUNC-
-TION FOR THE LARGE-SIGNAL SYSTEM” are performed
before the power is turned off, the voltage will be discharged in
about 30 seconds.
POWER SUPPLY UNIT ....................................................(205 V)
50 X MAIN DRIVE Assy...................................(–180 V to 205 V)
50 X SUB DRIVE Assy......................................(–180 V to 205 V)
50 Y MAIN DRIVE Assy....................................................(500 V)
50 Y SUB DRIVE Assy.......................................................(350 V)
50 SCAN A Assy..................................................................(500 V)
50 SCAN B Assy..................................................................(500 V)
: Part is the High Voltage Generating Points
other than the Charged Section.
High Voltage Generating Point
50 SCAN B Assy 50 Y SUB DRIVE Assy 50 X SUB DRIVE Assy Conductive plate X
50 SCAN A Assy 50 Y MAIN DRIVE Assy 50 X MAIN DRIVE Assy
Charged Section
The places where the commercial AC power is used without
passing through the power supply transformer.
If the places are touched, there is a risk of electric shock. In
addition, the measuring equipment can be damaged if it is
connected to the GND of the charged section and the GND of the
non-charged section while connecting the set directly to the
commercial AC power supply. Therefore, be sure to connect the
set via an insulated transformer and supply the current.
1. Power Cord
2. AC Inlet
3. Power Switch (S1)
4. Fuse (In the POWER SUPPLY Unit)
5. STB Transformer and Converter Transformer
(In the POWER SUPPLY Unit)
6. Other primary side of the POWER SUPPLY Unit
: Part is Charged Section.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pioneer PDP-507XA and is the answer not in the manual?

Pioneer PDP-507XA Specifications

General IconGeneral
3D-
Depth115 mm
Width1224 mm
Height717 mm
Weight34100 g
Tuner typeAnalog
Pixel pitch- mm
Smart modesEnergy saving
Aspect ratio16:9
Product colorBlack
LED indicatorsY, Power
Noise reductionYes
RMS rated power26 W
AC input voltage220 - 240 V
Display diagonal50 \
Channels quantity99 channels
AC input frequency50 - 60 Hz
Display brightness1100 cd/m²
Display resolution1365 x 768 pixels
Display technologyPlasma
Number of speakers2
Teletext standardsTop-text
SCART ports quantity3
Supported video modes1080p
USB 2.0 ports quantity0
Contrast ratio (typical)4000:1
Annual energy consumption- kWh
Display diagonal (metric)127 cm
Analog signal format systemNTSC, NTSC 3.58, NTSC 4.43, PAL, PAL 60, PAL BG, PAL DK, PAL I, SECAM, SECAM B/G, SECAM D/K, SECAM L
Power consumption (standby)0.3 W
Power consumption (typical)341 W
Sound enhancement technologyFOCUS, SRS, TruBass
Supported graphics resolutions1024 x 768 (XGA), 1280 x 768 (WXGA), 640 x 480 (VGA), 800 x 600 (SVGA)
Component video (YPbPr/YCbCr) in1
On Screen Display (OSD) languagesCZE, DAN, DEU, DUT, ENG, ESP, FIN, FRE, GRE, ITA, NOR, POL, POR, RUS, SWE, TUR