Chapter 62 ULSM Configuration
71-2
2. Configure the sFlow proxy address
Command
Explanation
Global Mode
sflow agent-address <collector-address>
no sflow agent-address
Configure the source IP address applied by
the s
Flow proxy; the “no” form of the
command deletes this address.
3. Configure the sFlow proxy priority
Command
Explanation
Global Mode
sflow priority <priority-vlaue>
no sflow priority
Configure the priority when sFlow receives
packet from the hardware; the “
no sflow
priority” command restores to the default
4. Configure the packet head length copied by sFlow
Command
Explanation
Port Mode
sflow header-len <length-vlaue>
no sflow header-len
Configure the length of the packet data head
copied in the sFlow data sampling; the “no”
form of this command restores to the default
value.
5. Configure the max data head length of the sFlow packet
Command
Explanation
Port Mode
sflow data-len <length-vlaue>
no sflow data-len
Configure the max length of the data packet in
sFlow; the “no” form of this command restores
to the default.
6. Configure the sampling rate value
Command
Explanation
Port Mode
sflow rate {input <input-rate> | output
<output-rate >}
no sflow rate [input | output]
Configure the
sampling rate when sFlow
performing hardware sampling. The “no”
command deletes the rate value.
7. Configure the sFlow statistic sampling interval
Command