Poseidon SE7EN+ User Manual Chapter 3 Page 64
Safe diving with the Poseidon SE7EN+
• NEVER hold your breath when breathing underwater!
• ALWAYS rell the CO
2
absorbent cartridge with fresh Sofnolime 797 whenever the oxygen
cylinder is refilled or replaced, see Chapter 1, section 14. Scrubber.
• ALWAYS remove the sponge from the top and bottom of the CO
2
absorbent cartridge after
every dive and squeeze as much moisture out of the sponge as possible. It is extremely
important to allow this sponge to dry as much as possible before starting a new dive.
• IIf you feel the mouthpiece vibrate for more than a brief pulse, bailout IMMEDIATELY and
look at the display.
• If you hear the audio alarm, IMMEDIATELY check the LCD display and prepare to terminate
the dive.
• If the Heads-Up Display light on the mouthpiece is STEADY ON, then ASCEND at a safe
and controlled rate to the surface.
• If the Heads-Up Display (HUD) light on the mouthpiece FLASHES, then STOP, look at the
LCD screen. A short single ash is a reminder to you to keep track of your PO
2
, which is
shown in the upper left eld of the display. If there is a problem, the HUD light will continue
to ash, and there may be a symbol in the upper right eld of the display ashing to indicate
the nature of the problem. For example, the directional arrows advise you to go up (ascend)
if you need to end the dive or if you need to go shallower; or go down (descend) if you have
ascended above a required decompression ceiling. Other elds on the display may ash to
indicate what the problem is. More information on the functionality of the display is pre-
sented in Chapter 3.
IMPORTANT:
Do NOT remove the battery while the electronics system is active.
Failure to complete a proper shut-down procedure will cause
the battery CPU to remain active, and drain the power supply
unnecessarily.
• When in doubt, bail out - switch to open-circuit (OC) and ascend in a controlled manner to
the surface.
• The default setpoint control algorithm is designed to allow for hands-off control of the
system PO
2
during all phases of a dive. The Poseidon SE7EN+ uses a proprietary method
that begins with a default control setpoint on the surface of 0.5 bar and gradually increases
PO
2
to a maximum automatic value of 1.2 bar at a depth of 15 m / 50 ft. Beyond this depth
the system will automatically control to a setpoint of 1.2 bar to the maximum operating
depth of the rig at 40 m.
IMPORTANT:
Do NOT remove the battery when the battery or the e-module is
wet to avoid problems with corrosion in the battery connectors or
the e-module’s battery connectors. Corrosion in the connectors
can cause power- or communication failure.