Ether232Plus User Guide Appendix B: Troubleshooting and Support
02-CML000027 Precidia Technologies Inc. B-7
COM – TRANSMIT lamp
Illuminates when the Ether232Plus is sending or receiving data via the COM port
Normally you will see very short data bursts.
COM – STATUS lamp
This lamp indicates the status of the network connection.
Table B.6: COM TRANSMIT Lamp Troubleshooting
Lamp Status Standard Troubleshooting Practice
On OK - In con-
figuration
mode
Finish configuring the Ether232Plus and exit from
configuration mode.
Flashing OK - data is
being trans-
mitted
None
Off No data is
being trans-
mitted
Ensure the serial cable between the
Ether232Plus and the serial device is properly
connected
Was the configuration recently changed? Look
at the System Status page to check the system
uptime. If it is a short period, check the config-
uration of the Ether232Plus to see if it has
been modified recently. Please refer to
Sections 3 and 4 for further information.
Table B.7: COM STATUS Lamp Troubleshooting
Lamp Status Standard Troubleshooting Practice
On Network con-
nection is
established
None
Slow
Flash
OK - no
activity
present
None
Fast
Flash
OK -
attempting
connection to
remote host
None