iPocket232 User Guide Appendix F: MCC
23-CML000293 iPocket232 Inc. F-3
Table F.1: Supported Commands
Command Description Syntax
Syntax
A[pppp]
ANSWER
Allows the iPocket232 modem to listen for a
connection or accept a connection on the provided
port [pppp]
Successful connection returns a “CONNECT
<speed>” message. Otherwise, the modem waits
indefinitely, or until a key is pressed to cancel.
If no port number is specified, the modem uses the
configured Local Port. If Local Port is 0, the modem
uses the standard telnet port (23).
The modem provides a “RING” message when an
incoming connection is received and auto-answer is
not active.
Note: A telnet program is already listening on port
23 if the Remote Password has been set. If this
command is also input, you will get an “ERROR”
message.
[pppp]
The listening port number,
range 0-65535 [pppp].
Dstring
DIAL
Attempts a connection to the specified IP address. If
the IP is specified, but port is not, the modem uses the
telnet port (23).
If a dial string is invalid or not specified, the modem
uses the Remote IP and Remote Port.
If Remote Port is 0, the modem uses the Fallback IP and
Fallback Port.
string =
aaa.bbb.ccc.ddd:pppp
aaa.bbb.ccc.ddd is the IP
address in standard
notation
pppp is the port number
(065535)
Note: Any non-digit can
replace the “.” or “:”.
DS=n or
DSn
DIAL STORED
Attempts a connection to a stored IP address and port
number.
n = 0 (or no option
present) uses
Remote location
n = 1 uses Fallback
location
En
ECHO Allows host commands to be
echoed.
n = 0 (no option present)
will disable echo
n =1 enables command
mode echo (default)