27
Parameters | Determining factors
User Manual | Agrónic 2500
Definitive stop
Temporary stop
Conditional stop
Start
Start / Stop
Warning
Modify irrigation
Modify fertilizer
End due to rain
Filter pressure gage
Diesel pressure gage
Stop fertilizer
Type
Digital sensor
origin
Analog sensor
origin
Meter sensor
origin
Flow error origin
Origin
Communication
Relation between types of determining factors and the origin that can be used:
Common parameters for all
DETERMINING FACTOR PARAMETERS
Determining factor 18
SMS to tel. A: yes
SMS to tel. B: yes
SMS text C: 0
It is an anomaly: yes
To all programs: no
In error: does not change
Text: abcdefghi
SMS to tel. A (Yes ... No): when the determining factor is
activated, send an SMS to phone A.
SMS to tel. B (Yes ... No): when the determining factor is
activated, send an SMS to phone B.
SMS to tel. C (0 ... 6): when the determining factor is
activated, send an SMS to phone C with the selected.
Urgent send (Yes ... No): only used if the GPRS modem is
deactivated on a schedule.
Yes: if the modem is deactivated, it is activated to
send the SMS and deactivated again.
No: if the modem is deactivated, the SMS will be
sent when it is activated by schedule.
It is an anomaly (Yes ... No): yes when the determining
factor is activated, it is registered as a new anomaly.
In all programs (Yes ... No):
Yes: the determining factor is associated with all
Agrónic programs. It is not assigned to foggers.
No: the determining factor is associated with the
desired programs within ‘Function - 4. Parameters
- 5. Programs’.
In error (No change | Not active | Active): what to do if
there is an error in the sensor associated with the de-
termining factor.
No change: the determining factor maintains the
state.
Not active: the determining factor is deactivated.
Active: the determining factor is activated.
Text (0 ... 9 characters): identifying text of the determin-
ing factor.