Parameters | Determining factors
The determining factors are controls that act on ir-
rigation programs and records based on the value of
the sensors. The determining factor is related to the
programs in “Parameters – Programs”.
Each determining factor is assigned a specific
operative (stop, start, modify, warning, etc.), an origin
(digital, analog, meter, flow sensor, etc.), certain refer-
ences entered in the operatives, the type of record and
whether an SMS is sent.
Determining factor (0 ... 30): number of the determining
factor to configure.
Type (Not configured | Definitive stop | Temporary stop
| Conditional stop | Start | Start/Stop | Warning | Modify
irrigation | Modify fert. | End due to rain | Filter pres.
gauge | Diesel press.gauge | Stop fert.): determining
factor operative
• Not configured: the determining factor is not used.
• Definitive stop: for the associated programs until
manually reset.
• Temporary stop: for associated programs until the
next program start.
• Conditional stop: for associated programs while
the determining factor is active.
• Start: when the determining factor is activated, the
associated programs start.
• Start / Stop: when the determining factor is
activated, the associated programs start and when
it is deactivated they stop.
• Warning: when the determining factor is activated
or deactivated, a record is made.
• Modify irrigation: when a program starts, the irriga-
tion amount can be modified.
• Modify fert.: when a program starts, the EC
reference, if fertilizer by EC, or the fertilizer units, if
fertilizer uniformly, can be modified.
5.6. DETERMINING FACTORS
• End due to rain: when it has rained a certain
amount, irrigation does not start or stops if it is
active.
• Filter pres. gauge: to start filter cleaning.
• Diesel press. gauge: to indicate that the diesel
pump is activated.
• Stop fert.: when the determining factor for fertiliza-
tion is activated but irrigation continues.
Origin (Digital sensor | Analog sensor | Meter sensor |
Flow error | Communcation): type of sensor or output
associated with the determining factor.
• Digital sensor: associated with a digital sensor.
• Analog sensor: associated with an analog sensor.
• Meter sensor: associated with a meter sensor. Use
the instantaneous or total flow reading depending
on the type of determining factor.
• Flow error: associated with a meter sensor (high
and low flow errors, not receiving pulses when irri-
gating, receiving pulses when not irrigating).
• Communication: associated with the communi-
cation status with the AgroBee-L modules, the
computer or Cloud.
Depending on the origin of the determining factor,
the sensor associated with it is requested. There are
cases in which it is not requested because it is associ-
ated with an output, or because the sensor is already
defined by default.
Digital sensor No. (0 ... 20): associated digital sensor
number.
Analog sensor number (0 ... 40): analog sensor number.
Meter sensor number (0 ... 10): meter sensor number.