EasyManuals Logo

Progrés Agronic 2500 User Manual

Progrés Agronic 2500
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #53 background imageLoading...
Page #53 background image
53
User Manual | Agrónic 2500
Sensor: 01
Input No.: 00001
Status,
normally open: yes
Text:
Format: 01
No. of integers: 2
No. of decimals: 1
Sign: yes
Units: ºC
Calibration point 1:
real value: 00800 mV
Logical value: -30.0ºC
Calibration point 2:
real value: 00800 mV
Logical value: +60.0ºC
Calibration point 3:
real value: 00000 mV
Logical value: +00.0ºC
Calibration point 4:
real value: 00000 mV
Logical value: +00.0ºC
Sensor: 01
Input No.: 00001
Format: 01 +00.0 ºC
Tare: + 00.0ºC
Text:
DIGITAL SENSORS PARA.
ANALOG SENSORS PARA.ANALOG SENSORS PARA.
1 Erased
2 Events
3 Access codes
4 Activate options
5 Various
6 Communications
7 Language
8 Update soware
9 Backup copy
INSTALLER PARAMETERS
ENTER
or
10
Activated: yes
Schedule: 00:00 - 00:00
Determining factors:
00 00 00 00 00
00 00 00 00 00
PIVOT SOLAR IRRIGATION
ENTER
or
11
1 Sensors
2 Formats
Sensor: 01
Input No.: 00001
Type: digital
Pulse value: 01000.00L
Maximum time between
pulses: 120”
Flow in: 000.00 m3/h
Total in: 000.00 L/m2
Text:
1 Digital
2 Analog
3 Meters
ANALOG SENSORS PARA. METER SENSORS PARA.
SENSOR PARAMETERS
ENTER ENTER
ENTER
Screen:
automatic shut-o: yes
Illumination: yes
Contrast: 5
Keypad:
sound level: 2
PIN Security
PIN code: 0000
VARIOUS PARAMETERS
ENTER
or
9
or
2
or
3
or
8
ENTER
ENTERENTER
1
1
or
2
FUN

Other manuals for Progrés Agronic 2500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Progrés Agronic 2500 and is the answer not in the manual?

Progrés Agronic 2500 Specifications

General IconGeneral
BrandProgrés
ModelAgronic 2500
CategoryFarm Equipment
LanguageEnglish