53
User Manual | Agrónic 2500
Sensor: 01
Input No.: 00001
Status,
normally open: yes
Text:
Format: 01
No. of integers: 2
No. of decimals: 1
Sign: yes
Units: ºC
Calibration point 1:
real value: 00800 mV
Logical value: -30.0ºC
Calibration point 2:
real value: 00800 mV
Logical value: +60.0ºC
Calibration point 3:
real value: 00000 mV
Logical value: +00.0ºC
Calibration point 4:
real value: 00000 mV
Logical value: +00.0ºC
Sensor: 01
Input No.: 00001
Format: 01 +00.0 ºC
Tare: + 00.0ºC
Text:
DIGITAL SENSORS PARA.
ANALOG SENSORS PARA.ANALOG SENSORS PARA.
1 Erased
2 Events
3 Access codes
4 Activate options
5 Various
6 Communications
7 Language
8 Update soware
9 Backup copy
INSTALLER PARAMETERS
ENTER
or
10
Activated: yes
Schedule: 00:00 - 00:00
Determining factors:
00 00 00 00 00
00 00 00 00 00
PIVOT SOLAR IRRIGATION
ENTER
or
11
1 Sensors
2 Formats
Sensor: 01
Input No.: 00001
Type: digital
Pulse value: 01000.00L
Maximum time between
pulses: 120”
Flow in: 000.00 m3/h
Total in: 000.00 L/m2
Text:
1 Digital
2 Analog
3 Meters
ANALOG SENSORS PARA. METER SENSORS PARA.
SENSOR PARAMETERS
ENTER ENTER
ENTER
Screen:
automatic shut-o: yes
Illumination: yes
Contrast: 5
Keypad:
sound level: 2
PIN Security
PIN code: 0000
VARIOUS PARAMETERS
ENTER
or
9
or
2
or
3
or
8
ENTER
ENTERENTER
1
1
or
2
FUN

Other manuals for Progrés Agronic 2500