The sectors are the outputs where the irrigation valves
are connected. The sectors are related to pumps and
the irrigation meter. The history stores the irrigation
and fertilizer that each sector totals. The Agrónic 2500
can manage up to 30 sectors.
SECTOR PARAMETERS
Sector: 01
Sector 01
N. of output: 00001
N. of output: 00000
Sector 01
Pump 1: yes
Pump 1: no
Sector 01
Waterhammer temporization: +028 “
Sector (0 ... 30): sector number.
Output No.: the first question corresponds to the
digital output where the solenoid valve is connected.
This output cannot be assigned to any other sector or
general.
5.5. SECTORS
Output No.: the second question corresponds to the
auxiliary digital output. It may be common with other
sectors. Activated whenever any of the sectors that
have it configured are activated.
For output coding, see ‘6 Input and output coding’.
Pump 1 and 2 (Yes ... No):
• Yes: if the sector requires pump 1 and/or 2 to be
activated to irrigate.
Waterhammer temporization (-127 ... 000 ... +127): time
in seconds of delay between the opening and closing
of consecutive and general sectors.
• With positive values: the valve opens immediate-
ly when irrigation starts and stays open for the
number of seconds programmed when it ends.
• With negative values: the opening is delayed for
the number of seconds programmed and when ir-
rigation ends, it closes immediately. There may be
an exception if the sector is the last of an irrigation
sequence and the pump stopping timer is applied.
Example of the timer applied in the sequential irriga-
tion of three sectors:
Start/Stop a generator set
Video tutorial