User Manual | Agrónic 2500
Parameters | Determining factors
5.6.3 Start – Start and Stop
Start
Starts the associated programs when the determin-
ing factor is activated. This determining factor can be
limited with the program’s active schedule.
Start/Stop
It starts the associated programs when the determin-
ing factor is activated and stops them when the irriga-
tion units are deactivated or terminated. This deter-
mining factor can be limited with the program’s active
schedule.
Detection delay (0000 ... 9999”): the time that the deter-
mining factor must remain in order to activate or deac-
tivate the determining factor.
Origin: digital sensor
The determining factor is activated when the digital
sensor is activated for a period of time.
Origin: analog sensor and meter sensor
Reference: sensor value from which the determining
factor is activated or deactivated.
Dierential: margin between activation and deactiva-
tion of the determining factor.
When surpassed (Yes ... No):
• yes: if (value > reference) active determining factor.
If (value < reference – dierential) non-active
determining factor.
• No: If (value < reference) active determining factor.
If (value > reference + dierential) non-active
determining factor.
Program 5
Sector 3
Frequency, 1 (daily)
Start by determining factor (8)
Units: 30 m3
Example:
start due to analog sensor for
soil moisture content.
Determining factor 8
START
Analog sensor
Reference: 28% soil moisture content
When surpassed: no