User Manual | Agrónic 2500
Parameters | Programs
The programs are those that manage crop irrigation
and fertilization. They control the opening and closing
of sectors and fertilization. The Agrónic 2500 has 50
programs.
PROGRAM PARAMETERS
Program: 12
Type of start: [schedule]
[sequential]
[deter. fact.]
Program 12
Units of irrigation: [hh:mm]
[m3]
[m3/ha]
[mm’ss”]
[hh:mm/ha]
Program (0 ... 50): program number to be configured.
Start-up type (schedule | sequential | determining
factor): determines how the program is to be started.
• Schedule: starts at a certain time.
• Sequential: starts when another program ends.
• Determining factor: starts when a determining
factor is activated. The determining factor must be
‘Start’ or ‘Start/Stop’ type and must be assigned to
the program.
If the Sequential with 99:00 option is activated in
‘Function - 4. Parameters - 10. Installer - 5. Various’,
changing the start schedule to sequential can be
entered in the program. There is no need to do it from
parameters.
Irrigation Units (hh:mm | m3 | m3/ha | mm’ss” | hh:mm/
ha): determines which units the program will use for ir-
rigation. When the units are volume (m3), the irrigation
meter must be configured.
• hh:mm: hours and minutes.
• m3: cubic meters.
• m3/ha: cubic meters per hectare. The area of each
sector needs to be configured. With the area and
its correction coeicient, it determines the m3 of
irrigation that corresponds to it.
5.4. PROGRAMS
• mm’ss”: minutes and seconds.
• hh:mm/ha: time per hectare. The expected flow
rate and the area of each sector must be config-
ured. Irrigation programming is in m3/ha but irriga-
tion will be in hh:mm. With the area and its correc-
tion coeicient, it determines the m3 of irrigation
that corresponds to it and with the planned flow, it
converts it into time (hh:mm). Ideal for irrigating in
m3/ha and an irrigation meter is not available.
Pre-irrigation: time or volume that must transpire
before starting fertilization. The units and format are
the same as irrigation. At 0, fertilization begins the
same as irrigation.
Post-irrigation: time or volume that must transpire
between fertilizer termination and the program ter-
mination. The units and format are the same as irriga-
tion. If fertilizer has not yet finished when it arrives at
post-irrigation, it stops and anomaly 26 is recorded. If
irrigating and fertilizer by time and the fertilization is
series or parallel, there is no need to start pre-irriga-
tion. It is automatically calculated based on the post-ir-
rigation and fertilization time.
PROGRAM PARAMETERS
Program 12
Days of the week: no
Priority: 1
Program 12
Determining factors: 05 06 00 00 00
Program 12
Safety time
between starts: 00:00
Program 12
Text: abcdefghi
Days of the week (Yes ... No): if the start type is sequen-
tial, it is not asked.
• Yes: the program will ask for the days of the week.
For example, irrigate on Mondays and Thursdays.
• No: the program will irrigate according to the
frequency of days. For example, irrigate every
three days.