User Manual | Agrónic 2500
Parameters | Determining factors
5.6.9 Stop fertilizer
Stops fertilization and associated programs until the
next start, irrigation continues without fertilization.
The fertilizer units remaining in the program are lost.
It can only be activated if there is an associated irri-
gation and fertilizer program. When fertilization stops,
anomaly 26 is recorded.
Detection delay (0000 ... 9999”): the time that the deter-
mining factor must remain to activate or deactivate the
determining factor.
Origin: digital sensor
The determining factor is activated when the digital
sensor is activated for a period of time.
Origin: analog sensor and meter sensor
Start-up delay (0000 ... 9999): when a program starts
during this time, the determining factor is not calculat-
ed. In the case of sequential programs, it only applies
to the start of the first program.
Reference: sensor value from which the determining
factor is activated or deactivated.
When surpassed (Yes ... No):
• yes: the determining factor is activated if the
sensor value is higher than the reference (value >
reference).
• No: the determining factor is activated if the sensor
value is lower than the reference (value < reference).
Origin: flow error
Delay with no pulse (000 ... 255’): time in minutes that
must transpire without receiving pulses from the meter
to activate the determining factor. (At 0 there is no
meter error control).
Origin: communication
Use the communication status with the AgroBee, the
PC or Cloud.
Unit (AgroBee | PC):
• AgroBee: when the Agrónic does not have commu-
nication with the AgroBee, the determining factor
is activated. The determining factor only aects
programs that have sectors with outputs assigned
to the AgroBee.
• PC: when the Agrónic does not have communi-
cation with the PC or the Cloud, the determining
factor is activated.
Module (01 ... 20): when the unit is the AgroBee, enter
the AgroBee number. The determining factor is
activated when there is no communication with any of
the AgroBee-Ls (leaving it at 0) or with the AgroBee-L
configured here.
User (0 ... 3): when the unit is the PC, enter the user
number. The determining factor is activated when
there is no communication with any of the users
(leaving it at 0) or with the user configured here. For
communication with the Cloud, enter user 3.
DETERMINING FACTOR PARAMETERS
Determining factor: 08 Type: stop fertilizer
Origin: digital sensor
Digital sensor No.: 01
Delay, detection: 0030”
Origin: analog sensor
Analog sensor No.: 02
Delay, detection: 0150”
Reference: 02.1 mS
When surpassed: yes
Origin: meter sensor
Meter sensor No.: 02
Delay, detection: 0000”
at start: 0000”
Reference: 000.00 L/h
When surpassed: no
Origin: flow error
Meter sensor No.: 02
Delay without pulse: 006 ‘