EasyManua.ls Logo

Progrés Agronic 2500 - 5.10.SOLAR IRRIGATION

Progrés Agronic 2500
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
44
User Manual | Agrónic 2500
Parameters | Solar irrigation
Solar irrigation is used when the installation has a
hybrid power system: grid power or diesel and solar
panels.
SOLAR IRRIGATION PARAMETERS
Activated: yes
Schedule: 00:00 – 00:00
Determining factors:
00 00 00 00 00
00 00 00 00 00
With solar irrigation activated, the Agrónic selects
where it must use the power from through the pumps:
P1: activated when power is from the grid or diesel
P2: activated when the power is solar.
Sectors that use the hybrid system must have both
pumps assigned. The Agrónic, depending on the pa-
rameters it has configured, will decide whether to
activate P1 (mains or diesel) or P2 (solar). Both pumps
are never activated at the same time.
5.10. SOLAR IRRIGATION
Activated (Yes ... No):
Yes: the installation has a hybrid power system.
No: the installation has a single power system.
Normal use of Agrónic.
Schedule: only solar power is used within the schedule
configured here. Outside of these hours, both types of
power can be used. If it is le at 0 all day, both types of
power will be used.
Determining factors (00 ... 30): up to ten determining
factors that aect solar irrigation can be configured.
Leaving 0 there is no determining factor. The determin-
ing factors are conditional stop and normally linked to
a radiation sensor. Radiation indicates whether there
is enough power to carry out solar irrigation. These
determining factors are used to decide whether to use
solar power, grid power or diesel.