2 Supplementary operating instructions for Modbus RTU
2.1 About this Modbus pump............................................ 26
2.2 Control elements......................................................... 27
2.3 Electrical installation................................................... 27
2.4 Setting options for the pump control elements........... 30
2.5 “Modbus RTU” implementation................................... 31
2.5.1 “Modbus RTU” message structure........................... 32
2.6 Device monitoring....................................................... 33
2.7 Emergency mode........................................................ 34
2.8 Functional faults.......................................................... 34
2.9 Accessories................................................................ 35
2.10 Modbus RTU for Prominent pumps register............. 35
2.10.1 “Device identification” register...............................
36
2.10.2 “Modbus” register................................................... 36
2.10.3 “Production data pump assembly-specific” reg‐
ister........................................................................ 37
2.10.4 “Production data Modbus module-specific” reg‐
ister........................................................................ 38
2.10.5 “Current operating parameters” register ............... 39
2.10.6 “Target operating parameter” register.................... 42
2.10.7 “Advanced configuration” register.......................... 43
2.10.8 “Accessories 1” register......................................... 46
2.10.9 “Accessories 3” register......................................... 46
2.10.10 “Debug data” register........................................... 47
2.1 About this Modbus pump
Metering pumps DULCO flex Control DFXa with a “Modbus RTU”
connector differ from standard pumps by way of the connection
option to a “Modbus RTU” bus system. A “Modbus RTU” pump
DULCO flex Control DFXa can either be connected to a “Modbus
RTU” bus or be used as a stand-alone unit.
Example:
n Measured value-dependent metering of sodium hypochlorite
into a swimming pool water circuit, where the pump is con‐
trolled by a PLC in
‘Modbus RTU’
operating mode.
A “Modbus RTU” version of the DULCO flex Control DFXa (identity
code feature “Control option” = M) is intended for integration into a
“Modbus RTU” system.
This document contains general information for the implementation
of the metering pump DULCO flex Control DFXa, DFXa into the
serial communication protocol of the Modbus RTU.
Supplementary operating instructions for Modbus RTU
26

Table of Contents

Other manuals for ProMinent DULCO flex Control

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ProMinent DULCO flex Control and is the answer not in the manual?

ProMinent DULCO flex Control Specifications

General IconGeneral
BrandProMinent
ModelDULCO flex Control
CategoryWater Pump
LanguageEnglish

Related product manuals