EasyManuals Logo

ProMinent DULCO flex Control Supplementary Operating Instructions

ProMinent DULCO flex Control
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
Index Sub Name Type Description Categ.* Attr
6026h 00h
HighestSubIndex
Error notification
control
MANDA CO
02h Name String 0xA MANDA RW
03h Class String 0sB MANDA RW
07h NotificationCode U16 0 OPTION RW
6027h 00h
HighestSubIndex
Error notification
status
MANDA
01h Status U8 0 MANDA RO
Tab. 7: Category legend *
Abbreviation Full word
MANDA Mandatory
OPTION optional
CONDIT Conditionally mandatory
1.7.4 Alarm Action Area for Measurement Devices (404 )
Index Sub Name Type Description Categ. Attr
6519h 1 Al2_action =0 inac‐
tive
U8 Level min warning RW
6529h 1 Al3_action U8 Batch error RW
6539h 1 Al4_action U8 Cal warning RW
6549h 1 Al5_action U8 Sys error RW
6559h 1 Al6_action U8 Not bus RW
6569h 1 Al7_action U8 add2 RW
6579h 1 Al8_action U8 add3 RW
1.7.5 EMERGENCY
Tab. 8: Emergency Object Data:
Byte 0 1 2 3 4 5 6 7
Content* Emergency Error
Code*
Error reg‐
ister*
Manufacturer specific Error Field*
Tab. 9: *
Content (1 byte): 80h+Node-ID
Emergency Error Code (2 bytes): 0x1000 (0x10xx = Generic Error)
0x0000 (0x00xx = No Error)
Supplementary operating instructions for CANopen
19

Table of Contents

Other manuals for ProMinent DULCO flex Control

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ProMinent DULCO flex Control and is the answer not in the manual?

ProMinent DULCO flex Control Specifications

General IconGeneral
BrandProMinent
ModelDULCO flex Control
CategoryWater Pump
LanguageEnglish

Related product manuals