* R = read, W = write
Tab. 40: Mode, Flow rate, Max. flow rate, Batch, Contact, Concentration, Metering monitor
Module
/ slot
Index Name Module
name
Identifi‐
cation
(hex)
Type Data
flow *
Description
3 1 Mode Mode C0,80,8
0
u8 R, W Value Name Description
0.16 Halt Pump is ready
but not metering.
1 Manual Pump is metering
continuously with
the set volume
2 Batch When triggered,
the pump is
metering the
volume set in the
batch pre-selec‐
tion
3 Contact Pump is metering
volumes in the
specified time
R, W 4 Ana‐
logue
Pump is metering
in accordance
with the analogue
signal and ana‐
logue mode set
on the pump.
17 Manual
(con‐
centr.)
Manual in con‐
centration mode
18 Batch
(con‐
centr.)
Batch in concen‐
tration mode
19 Contact
(con‐
centr.)
Contact in con‐
centration mode
20 Ana‐
logue
(con‐
centr.)
Analogue in con‐
centration mode
Setting Bit 4
(+16) activates
concentration
mode (e.g. set
“Analogue
normal” with “4”;
set “Analogue
concentration”
mode with “20”)
Setting Bit 7
(+128) sets the
direction of rota‐
tion
Bit 7 = 1 ->
Counter-clock‐
wise rotation
Bit 7 = 0 ->
Clockwise rota‐
tion
Supplementary operating instructions for PROFINET
®
68