Chapter 3 Software
PA-6225 SERIES USER MANUAL
Page 78
Setting : Printer uses flags to make settings, and those settings affect the following data.
○: Enabled.
: Enabled only when the command is set at the beginning of a line.
●: Enabled only when data is not present in the printer buffer.
▲: Only value setting is possible.
Disabled: Parameters are processed as printable data.
Ignored: All command codes including parameters are ignored and nothing is executed.
COMMANDS DETAILS
STANDARD COMMANDS DETAILS
HT
[Name]
Horizontal tab
[Format]
ASCII HT
Hex. 09
Decimal 9
[Range]
N/A
[Description]
Moves print position to next horizontal tab position.
This command is ignored if the next tab is not set.
If the next tab position exceeds the print region, the print position is
moved to [print region + 1].
The horizontal tab position is set by ESC D (Set/cancel horizontal tab
position).
When the print position is at the [print region + 1] position and this
command is received, the current line buffer full is printed and a horizontal
tab is executed from the top of the next line.
The initial value of the horizontal tab position is every 8 characters of Font
A (the 9th, 17th, 25th positions, etc.)
LF
[Name]
Print and line feed
[Format]
ASCII LF
Hex. 0A
Decimal 10
[Range]
N/A
[Description]
Prints the data in the print buffer and performs a line feed based on the set line
feed amount.
After execution, makes the top of the line the next print starting position.