Proton Products SL mini and SLR mini Series Speed and Length Gauges Instruction Manual - issue 1s
Proton standard RS232 parameter access protocol
This uses a protocol to access individual parameters or blocks of parameters and is typically used in a
production line environment where the gauge is connected to a PLC or similar device.
Notes
- The parameters are split into ‘Input’ and ‘Output’ groups, the ‘Input’ parameters can be both read
and written, and the ‘Output’ parameters can only be read
- The parameter number is the same as the word address used for Profibus data; refer to the
‘PROFIBUS Master to Gauge and RSβγβ Input Parameter List’ for the parameter numbers
- For ‘Input’ data: when a word is defined as bits then four hexadecimal characters are required to
form the bits 15~0; when a word is defined as a data value then only sufficient characters to define
the value in decimal format, with the decimal point where appropriate, are needed; where the data
is of double word length then only the first word address is used
- For ‘Output’ data: when a word is defined as bits then four hexadecimal characters will be sent;
when a word is defined as a data value it is converted to a decimal number with the decimal point
but without leading zeros; where a double word is used then only the first word address is used to
request the data, the data in both words is automatically converted to a single value
- If a PC keyboard is being used to enter the codes then the ‘carriage return’ plus ‘line feed’ are
replaced by the Enter key
SET THE VALUE OF AN ‘INPUT PARAMETER
Write Format:
&
Input Parameter number
Space
Value without decimal point [0.5m = 50]
Carriage return
Line feed
REQUEST VALUE ONCE FOR ONE OR A RANGE OF ‘INPUT PARAMETERS
Request Format 1: (e.g.: ?β ‘ENTER’)
?
Input Parameter number
Carriage return
Line feed
Request Format β: (e.g.: ?β β ‘ENTER’)
?
Input Parameter number
Space
Length of string
Carriage return
Line feed

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Proton SL mini 3060 and is the answer not in the manual?

Proton SL mini 3060 Specifications

General IconGeneral
BrandProton
ModelSL mini 3060
CategorySecurity Sensors
LanguageEnglish

Related product manuals