This  view  shows  you  the  Leq,  Peak, 
and C-A values with a choice of  A, C 
and Z frequency weightings.  
 
The  C-A  data  can  be  used  with  the 
HML  method  for  selecting  hearing 
protection.  
 
If  the  Time  Weighting  is  set  to 
Impulse, the C-A function is replaced 
by LAeq,I (also known as LAIeq). 
 
When  the  instrument  is  set  to  the 
German  language,  an  additional 
‘Taktmaximal’ page is also available. 
 
The  Dose  View  shows  you  a  number 
of different functions depending upon 
the  configuration  of  the  Quick 
Settings.  
 
For  the  UK  option,  this  View  gives 
you  Leq,  LEP,d,  %  Dose  and 
Estimated  Dose  along  with  the 
Projected Exposure Calculator. 
 
For  the  EU  option,  this  View  gives 
you  Leq,  LEX,8,  %  Dose  and 
Estimated  Dose  along  with  the 
Projected Exposure Calculator. 
 
For  all  other  options  the  Lavg,  TWA, 
%  Dose  and  Estimated  %  Dose  for 
two  integrators,  in  addition  to  ISO 
(EU),  will  be  shown  according  to  the 
setting you have chosen. 
 
Two  custom  integrators  can  also  be 
used,  configured  in  AnalyzerPlus. 
When  chosen,  they  will  be  shown  in 
addition to ISO (EU).