EasyManuals Logo
Home>Pyronix>Control Panel>STERLING 10

Pyronix STERLING 10 Installation Manual

Pyronix STERLING 10
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #25 background imageLoading...
Page #25 background image
Sterling 10 Installation Manual
RINS1413-1 Page 21
5.6.4 System Options 4
Function Keypress Icon Option Off (Icon Off) Option On (Icon On) OFF ON Save
 
Abort Digi Active Low Abort Digi Active High

Open Digi Active Low Open Digi Active High

Service Timer Warning on Expire if programmed
with Function 27
Service Timer Warning and Lockout System on
Expire

Anti-code Reset Disabled Anti-Code Reset Enabled
= Default
5.7 Programmable Rearms
Function Number of Rearms Default Key

|__|
0 0 = Continuous Rearms
1...9 = Number of Rearms
5.8 Service Timer
Function Arm/Disarm Cycles Default Key

|__|
0 Time Between Services
Arm/Disarm
Cycles/Day
30 Days 6 Months 12 Months
1 1 4 7
4 2 5 8
6 3 6 9
0 = No Service Timer

Other manuals for Pyronix STERLING 10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix STERLING 10 and is the answer not in the manual?

Pyronix STERLING 10 Specifications

General IconGeneral
BrandPyronix
ModelSTERLING 10
CategoryControl Panel
LanguageEnglish

Related product manuals