Sterling 10 Installation Manual
RINS1413-1 Page 21
5.6.4 System Options 4
Function Keypress Icon Option Off (Icon Off) Option On (Icon On) OFF ON Save
 
Abort Digi Active Low Abort Digi Active High

Open Digi Active Low Open Digi Active High

Service Timer Warning on Expire if programmed
with Function 27
Service Timer Warning and Lockout System on
Expire

Anti-code Reset Disabled Anti-Code Reset Enabled
= Default
5.7 Programmable Rearms
Function Number of Rearms Default Key

|__|
0 0 = Continuous Rearms
1...9 = Number of Rearms
5.8 Service Timer
Function Arm/Disarm Cycles Default Key

|__|
0 Time Between Services
Arm/Disarm
Cycles/Day
30 Days 6 Months 12 Months
1 1 4 7
4 2 5 8
6 3 6 9
0 = No Service Timer