Sterling 10 Installation Manual
RINS1413-1 Page 29
6.5 PGM Programming
6.5.1 PGM 1 (Function 20)
Press 
This starts the function
ENTER SEQUENCE
Enter the PGM type to .
NOTE: Default is 0 (Not Used).
0 = Not Used
1 = PIR Remote LED Enable
2 = PIR Latch Memory
3 = Shock Sensor Reset
ENTER SEQUENCE
0
The new type will save automatically.
You will be returned to engineer mode.
6.5.2 PGM 2 (Function 21)
Press 
This starts the function
ENTER SEQUENCE
Enter the PGM type to .
NOTE: Default is 0 (Not Used).
0 = Not Used
1 = PIR Remote LED Enable
2 = PIR Latch Memory
ENTER SEQUENCE
0
The new type will save automatically.
You will be returned to engineer mode.
6.6 System Options
6.6.1 System Options 1 (Function 22)
Press 
This starts the function
ENTER SEQUENCE
x x x x
Use keys to to toggle the
options on or off.
Example shows option 2 on.
ENTER SEQUENCE
x x x
Press
You will be returned to engineer mode.
Options:
Option Option On ( ) Option Off (
x
) (Default)
1 Silent P.A. Audible P.A.
2 User Log Reset Enabled User Log Reset Disabled
3 Engineer Only System Reset User System Reset
4
External & Internal Sounders on Tamper
Activation
Internal Sounder Only on Tamper Activation

Other manuals for Pyronix STERLING 10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix STERLING 10 and is the answer not in the manual?

Pyronix STERLING 10 Specifications

General IconGeneral
BrandPyronix
ModelSTERLING 10
CategoryControl Panel
LanguageEnglish

Related product manuals