Sterling 10 Installation Manual
RINS1413-1 Page 31
6.6.4 System Options 4 (Function 25)
Press
This starts the function
ENTER SEQUENCE
x x x
Use keys to to toggle the
options on or off.
Example shows option 2 off.
ENTER SEQUENCE
x x x x
Press
You will be returned to engineer mode.
Options:
Option Option On ( ) Option Off (
) (Default)
1 Abort Digi Active High Abort Digi Active Low
2 Open Digi Active High Open Digi Active Low
3
Service Timer Warning & Lockout System on
Expire
Service Timer Warning on Expire if
programmed with Function 27
4 Anti-Code Reset Enabled Anti-Code Reset Disabled
6.7 Programmable Rearms (Function 26)
Press
This starts the function
ENTER SEQUENCE
Enter the number of rearms to .
NOTE: Default is 0 (Continuous).
0 = Continuous
1 - 9= Number of Rearms
ENTER SEQUENCE
0
The number will save automatically.
You will be returned to engineer mode.
6.8 Service Timer (Function 27)
Press
This starts the function
ENTER SEQUENCE
Enter the number of arm and disarm
cycles between service intervals to
.
NOTE: Default is 0 (No timer).
Time Between Services
Arm/Disarm
Cycles Per
Day
30
Days
6
Months
12
Months
1