Sterling 10 Installation Manual
RINS1413-1 Page 25
6. LCD PROGRAMMING
6.1 Entering/Exiting Engineer Mode
Press 
where  is the
engineer code (default 9999)
Enter Engineer mode
ENGINEER MOD
E
Press 
where  is the
engineer code (default 9999)
Exit Engineer mode
SYSTEM ARMED SYSTEM ARMED SYSTEM ARMED SYSTEM ARMED SYSTEM ARMED SYSTEM ARMED SYSTEM ARMED SYSTEM ARMED SYSTEM ARMED SYSTEM ARMED SYSTEM ARMED SYSTEM ARMED SYSTEM ARMED SYSTEM ARMED SYSTEM ARMED
6.2 Zones
6.2.1 Arm Mode A (Function 10)
Press 
This starts the function
ENGINEER MODE
1 ENTRY / EXIT
Zone 1 is displayed.
Use the and keys to scroll
through the zone types available.
Press the key to accept.
This is repeated for Zones 2 – 8.
Zone Types:
Entry / Exit
Access
Immediate
Omit
Momentary Key
Latched Key
Tamper
24 Hour
Fire
ENGINEER MODE
2 ACCESS
ENGINEER MODE
3 IMMEDIATE
ENGINEER MODE
4 IMMEDIATE
ENGINEER MODE
5 IMMEDIATE
ENGINEER MODE
6 IMMEDIATE
ENGINEER MODE
7 IMMEDIATE
ENGINEER MODE
8 IMMEDIATE
The function is ended after saving
the zone type for zone 8
You will be returned to engineer mode.
Defaults
Zone Type Zone Zone Type Zone Type
1 Entry / Exit 3 Immediate 5 Immediate 7 Immediate
2 Access 4 Immediate 6 Immediate 8 Immediate

Other manuals for Pyronix STERLING 10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix STERLING 10 and is the answer not in the manual?

Pyronix STERLING 10 Specifications

General IconGeneral
BrandPyronix
ModelSTERLING 10
CategoryControl Panel
LanguageEnglish

Related product manuals