Sterling 10 Installation Manual
RINS1413-1 Page 27
6.2.4 Arm Mode D (Function 13)
Press 
This starts the function
ENGINEER MODE
1 ENTRY / EXIT
Zone 1 is displayed.
Use the and keys to scroll
through the zone types available.
Press the key to accept.
This is repeated for Zones 2 – 8.
Zone Types:
Entry / Exit
Access
Immediate
Omit
Momentary Key
Latched Key
Tamper
24 Hour
Fire
ENGINEER MODE
2 ACCESS
ENGINEER MODE
3 IMMEDIATE
ENGINEER MODE
4 IMMEDIATE
ENGINEER MODE
5 IMMEDIATE
ENGINEER MODE
6 IMMEDIATE
ENGINEER MODE
7 IMMEDIATE
ENGINEER MODE
8 IMMEDIATE
The function is ended after saving
the zone type for zone 8
You will be returned to engineer mode.
Defaults
Zone Type Zone Zone Type Zone Type
1 Entry / Exit 3 Immediate 5 Immediate 7 Immediate
2 Access 4 Immediate 6 Immediate 8 Immediate
6.3 Timers
6.3.1 Bell Time (Function 14)
Press 
This starts the function
ENTER SEQUENCE
Enter to  minutes.
NOTE: Default is 20 minutes.
Example shows 20 minutes.
ENTER SEQUENCE
20
Press
You will be returned to engineer mode.
6.3.2 Entry Time (Function 15)
Press 
This starts the function
ENTER SEQUENCE
Enter to  seconds.
NOTE: Default is 30 seconds.
Example shows 30 seconds.
ENTER SEQUENCE
30
Press
You will be returned to engineer mode.