Sterling 10 Installation Manual
RINS1413-1 Page 33
6.12 Anti-Code Algorithm (Function 31)
Press 
This starts the function
ENTER SEQUENCE
Enter the required Anti-Code Algorithm
to .
NOTE: This should be left at 0 (Default).
ENTER SEQUENCE
0
The configuration will save automatically.
You will be returned to engineer mode.
6.13 Exit Options
6.13.1 Arm Mode A Exit Options (Function 32)
Press 
This starts the function
ENTER SEQUENCE
Enter the required Exit Option to
.
NOTE: Default is 0 (Timed Exit).
0 = Timed Exit
1 = Push To Arm
2 = Final Door
ENTER SEQUENCE
0
The configuration will save automatically.
You will be returned to engineer mode.
6.13.2 Arm Mode B Exit Options (Function 33)
Press 
This starts the function
ENTER SEQUENCE
Enter the required Exit Option to
.
NOTE: Default is 0 (Timed Exit).
0 = Timed Exit
1 = Push To Arm
2 = Final Door
ENTER SEQUENCE
0
The configuration will save automatically.
You will be returned to engineer mode.