4 – Installation
Installing a Switch
4-2 59096-02 C
S
4.1.2
Switch Power Requirements
Power requirements are 1 Amp at 100 VAC or 0.5 A at 240 VAC.
4.1.3
Environmental Conditions
Consider the factors that affect the climate in your facility such as equipment heat
dissipation and ventilation. The switch requires the following operating conditions:
Operating temperature range: 5 – 40°C (41 – 104°F)
Relative humidity: 15 – 80%, non-condensing
4.2
Installing a Switch
Unpack the switch and accessories. The SANbox 5600 Series product is shipped
with the components shown in Figure 4-1:
SANbox 5600 Series Fibre Channel Switch (1) with firmware installed
Power cord (1) – model 5600
Power cords (2) – model 5602
Rubber feet (4)
Mounting brackets (2) – model 5600
CD-ROM containing the SANsurfer Switch Manager switch management
application, release notes, and documentation.