103
Italiano
Deutsch
English
Menu level summary table
First level Second
level
Third level D Notes
“C
-
C X Temperature in °C
F X Temperature in °F
-t-
Temperature
93/199
°C/°F
X If °C
from 40 to 105
93 Default
If °F from 104 to 221
199 Default
“”oFS
14°C/57°F X Set from 0-25°C or 32-77°F
“Pr1”
coffee
pre-infusion
“On”
“Oon”
deactivated
“1on” active pump 1s
“2on” active pump 2s
“8on” active pump 8s
“9on” active pump 9s
“Stb”
Setting
standby
0 X Deactivated
30 Active after 30 minutes
60 Active after 60 minutes
90 Active after 90 minutes
“Eco”
Setting
standby
0 X Deactivated
30 Active after 30 minutes
60 Active after 60 minutes
90 Active after 90 minutes
F 1.0 FW Power version
1.2 FW Display version
“Ts
-
Steam
temperature
130/266
°C/°F
If °C
from 130 to 140
130 Default
If °F from 266 to 284
266 Default

Table of Contents