EasyManuals Logo

Rae MultiRAE User Manual

Rae MultiRAE
93 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
MultiRAE User’s Guide
3
10 Calibration And Testing ........................................................................................................ 56
10.1 Manual Alarms Test ...................................................................................................... 56
10.2 Bump Testing And Calibration ..................................................................................... 56
10.2.1 MultiRAE Equipped With A Pump ........................................................................ 56
10.2.2 MultiRAE Lite Diffusion Model (No Pump).......................................................... 57
10.2.3 Bump (Functional) Testing ..................................................................................... 57
10.2.4 Testing The Gamma Radiation Sensor ................................................................... 59
10.3 Zero/Fresh Air Calibration ............................................................................................ 60
10.3.1 Zero Calibration For A CO
2
Sensor ........................................................................ 60
10.3.2 Zero Calibration For Parts-Per-Billion (ppb) Sensor .............................................. 60
10.3.3 Fresh Air Calibration .............................................................................................. 60
10.3.4 Single-Sensor Zero Calibration............................................................................... 61
10.4 Span Calibration............................................................................................................ 61
10.5 Three-Point Calibration For Enhanced Linearity With Extended-
Range And ppb PID Sensors......................................................................................... 61
10.5.1 Enabling 3-Point Calibration Via ProRAE Studio II .............................................. 62
10.5.2 Multi-Sensor Span Calibration ............................................................................... 64
10.5.3 Single-Sensor Span Calibration .............................................................................. 65
11 MultiRAE Pro Multi-Threat & Gamma Operation ............................................................... 66
11.1 Multi-Threat Mode For Simultaneous Radiation & Gaseous Threat Measurements . 66
11.2 Gamma Radiation-Only Measurement Mode ............................................................... 67
11.3 Gas-Only Measurement Mode ...................................................................................... 69
12 Datalog Transfer, Monitor Configuration, and Firmware Upgrades Via Computer ............ 71
12.1 Downloading Datalogs And Performing PC-Based Instrument
Configuration And Firmware Upgrades ....................................................................... 71
13 Maintenance .......................................................................................................................... 73
13.1 Removing/Installing The Rubber Boot ......................................................................... 73
13.2 Replacing The Filter(s) ................................................................................................. 73
13.3 Replacing The Gas Inlet Adapter (Pumped Versions Only) ......................................... 74
13.4 Removing/Cleaning/Replacing Sensor Modules .......................................................... 74
13.5 Removing/Cleaning/Replacing A PID (Pumped Versions Only) ................................. 75
13.6 Replacing The Pump ..................................................................................................... 77
14 Alarms Overview .................................................................................................................. 78
14.1 Alarm Signals................................................................................................................ 78
14.2 Changing The Alarm Mode .......................................................................................... 78
14.3 Alarm Signal Summary................................................................................................. 79
15 Troubleshooting .................................................................................................................... 82
16 Specifications ........................................................................................................................ 83
17 Technical Support ................................................................................................................. 87
18 RAE Systems Contacts ......................................................................................................... 88

Table of Contents

Other manuals for Rae MultiRAE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rae MultiRAE and is the answer not in the manual?

Rae MultiRAE Specifications

General IconGeneral
Operating Temperature-20°C to 50°C (-4°F to 122°F)
Humidity0% to 95% relative humidity (non-condensing)
BatteryRechargeable Li-ion battery
VOC measurement range0-5000 ppm
SensorsPID, LEL, O2, CO, H2S
Battery LifeUp to 18 hours
DisplayBacklit LCD
Data LoggingYes
CommunicationWireless (optional), Bluetooth
AlarmsAudible, visual, and vibrating alarms
PumpInternal pump
CertificationsATEX, IECEx, UL, CSA

Related product manuals