11 | Automatic cleaning
Original instructions for use 41 / 64
11 Automatic cleaning
Your iCombi Pro is equipped with an automatic cleaning system. Select the cleaning program, place the displayed
number of Active Green tabs and care tabs and the unit will clean itself. At the same time, the integrated care
system keeps the steam generator free of scale. This gives you a hygienically clean and optimally maintained unit
at all times.
11.1 General safety information
n
Only use the manufacturer’s recommended Active Green cleaner tabs and care tabs
in automatic cleaning.
To avoid scalding and burn injuries:
n
Allow the unit and all functional components to cool down before starting
automatic cleaning.
To avoid severe chemical burns:
n
Cleaning and care products can cause severe eye damage and chemical burns to
the skin. Always wear securely fitting safety eyewear and chemical-resistant
gloves when cleaning the unit.
n
Keep the cooking cabinet door closed during automatic cleaning. Otherwise, hot
steam and corrosive cleaning chemicals could escape. If you open the cooking
cabinet door during automatic cleaning, a warning signal will sound.
n
Make sure the core temperature probe is not dangling out of the unit while
automatic cleaning is in progress. This could damage the seal on the cooking
cabinet door and allow corrosive cleaning chemicals to escape.
n
Do not clean the externally attached core temperature probes using automatic
cleaning.
n
Before preheating the unit for cooking, remove all cleaning products and cleaning
product residues.
How to respond if you come into contact with cleaning chemicals:
n
If you touch cleaning agents when not wearing gloves or your skin otherwise
comes into contact with Active Green cleaner tabs, rinse your skin with running
water for 10 minutes.
n
If you get cleaning chemicals into your eyes, rinse your eyes with running water
for 15 minutes. Remove your contact lenses, if applicable.
n
If you swallow cleaning chemicals, rinse your mouth out with water and drink two
glasses of water immediately. Do not induce vomiting.
n
Call the poison control hotline or a doctor immediately.
11.2 Cleaning programs
The following cleaning programs are available to you:

Table of Contents

Other manuals for Rational iCombi Classic

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rational iCombi Classic and is the answer not in the manual?

Rational iCombi Classic Specifications