13 | Inspiration and help
50 / 64 Original instructions for use
Error report Cause Cooking possible
Service (E) 60
Gas system failed
The initialisation of the ignition box is
defective.
Switch the unit off and on again. If the
error is still displayed, call your Service
Partner.
13.3.3 Error messages heating hot air
Error report Cause Cooking possible
Service (E) 20.1
Cabinet sensor failed
The temperature probe is defective. No
Service (E) 28.1
Steam generator too hot
The temperature limit of the steam
generator has been exceeded.
No
Service (E) 28.2
Cooking cabinet too hot
The temperature limit of the cooking
cabinet has been exceeded.
No
Service (E) 34.1
Data communication failed
The internal data communication is faulty. No
Service (E) 34.2
Data communication failed
The internal data communication is faulty. No
Service (E) 34.4
Data communication failed
The internal data communication is faulty. No
Service (E) 42.3
Solenoid valve failed
The water supply is faulty. The steam injection function is
not available.
Service (E) 42.6
Solenoid valve failed
The water supply is faulty. Yes
Service (E) 43.3
Solenoid valve failed
The internal water supply is not closing. Only the convection mode is
available at the moment.
13.3.4 Error messages humidity
Error report Cause Cooking possible
Service (E) 20.2
Control sensor failed
The temperature probe is defective. Yes
Service (E) 20.4
Humidity sensor failed
The temperature probe is defective. Yes
Service (E) 30
Humidity control failed
The humidity measurement is incorrect. Yes
Service (E) 36
Humidity control failed
The differential pressure sensor is
defective.
Yes
Service (E) 37
Humidity control failed
The differential pressure sensor is
defective.
Yes
Service (E) 42.2
Solenoid valve failed
The water supply is faulty. Yes
Service (E) 43.2
Solenoid valve failed
The internal water supply is not closing. Only the convection mode is
available at the moment.