10 Faults and possible causes
WARNING!
Risk of injury due to incorrect troubleshooting
Delayed or incorrect repairs by unqualified personnel may result in severe personal injury as well
as in damages to the machine and the environment.
u
Any faults occurring must be repaired immediately.
u
Repairs may only be carried out by qualified personnel.
Troubleshooting requirements
Switch off the tractor engine and lock it to prevent unauthorized starting.
Park the machine.
Please take particular note of the warnings in chapter 3 Safety and 11 Maintenance and service.
Fault Possible cause Measure
Uneven fertilizer distribution Clumps of fertilizer on spreading
discs, spreading vanes and
outlet ducts.
u
Remove the clumps of
fertilizer.
The metering slides do not open
completely.
u
Check the function of the
metering slides.
Spreading vanes incorrectly
adjusted.
u
Correct the settings in
accordance with the fertilizer
chart information.