Wear parts are: Spreading vanes, agitator head, outlet, hydraulic hoses and all plastic parts.
Plastic parts are subject to a certain aging process even under normal spreading conditions. Plastic
parts are, e.g., protective grid locks, connecting rod.
Inspect wear parts on a regular basis.
Replace these parts if they show signs of wear, deformation, holes, or aging. Otherwise, the spreading
pattern will not be correct.
The durability of wear parts depends, among other things, on the material being spread.
11.2.2 Checking the screw connections
n
Screw connections
Screw connections have been tightened to the specified torque and locked at the factory. Vibrations
and shocks, in particular during the initial operating hours, can loosen screw connections.
u
Check all screw connections for tightness.
Some components are mounted with self-locking nuts.
u
When mounting these components, always use new self-locking nuts.
Observe the tightening torques of the standard screw connections.
See 14.1 Torque value
11.2.3 Checking the screw connections of the weigh cells
n
Screw connection of the weigh cells
The machine is equipped with 2 weigh cells and a tie rod. These elements are fixed by means of
screw connections.
11. Maintenance and service