EasyManua.ls Logo

Rauch MDS 8.2 - Evaluating Results; Correcting Settings

Rauch MDS 8.2
150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ü
Perform the test at the desired working speed.
ü
Spread along tracks 1 to 3 one after the other.
u
Open the metering slide 10 m before the collection trays.
u
Close the metering slides approx. 30 m behind the collection trays.
If the quantity collected in the collecting vessels is insufficient, repeat the passage.
Do not change the adjustment of the metering slides.
9.9.4 Evaluating results
u
Pool the contents of the collecting vessels placed one after another and pour them into the
measuring tubes from the left-hand side.
u
The quality of the horizontal spreading pattern can be read off the three measuring tubes.
Fig. 53: Possible results
A All tubes contain the same amount.
B Fertilizer distribution not symmetrical
C Too much fertilizer in the overlap zone
D Too little fertilizer in the overlap zone
9.9.5 Correcting settings
n
Examples for the correction of spreader settings
Test result Fertilizer distribution Action, test
Case A Even distribution (admissible deviation ±1
scale line)
Settings are correct.
9. Spreading operation
92
5902916 MDS 8.2/14.2/18.2/20.2

Table of Contents

Other manuals for Rauch MDS 8.2