[1] Flat spring
[2] Locking bolt
Fig. 77: Locking bolt properly engaged
11.10 Checking the agitator
n
Setting the agitator
u
Insert the agitator into the agitator shaft and engage the bayonet lock.
u
Pull the engaged agitator up with one hand.
Use a 1 mm thick washer or a metal strip to check.
The distance between the bottom edge of the agitator and the hopper base must now be 1 mm.
Fig. 78: Setting the agitator
Case 1: There is too much space between the agitator and the hopper base.
u
Remove washers from the 3 mounting screws of the transmission.
The transmission sits lower.
11. Maintenance and service
MDS 8.2/14.2/18.2/20.2 5902916
127