EasyManua.ls Logo

Rauch MDS 8.2 - Cleaning the Machine; Cleaning

Rauch MDS 8.2
150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Checking the protective grid lock
u
Perform a regular function check of the protective grid lock.
u
Replace defective protective grid locks immediately.
u
If required, correct the setting by moving the protective grid lock [1] up/down.
Fig. 67: Test dimensions for functional check of the protective grid interlock
11.4 Cleaning the machine
n
Cleaning
Spreading material and dirt promote corrosion. Although the machine components are made from
corrosion-free material, we recommend that you clean the machine immediately after each use to
maintain its value.
u
If available, fold up the protective grids in the hopper (depending on the machine).
u
Only clean oiled machines at washing points fitted with an oil separator.
u
When cleaning with high-pressure, never aim the water jet directly at warning signs, electrical
equipment, hydraulic components, and sliding bearings.
u
Preferably clean the machine using a gentle water jet.
u
Especially clean the air ducts, injectors, and bends.
u
After cleaning, treat the dry machine, especially the stainless steel parts, with an
environmentally friendly anti-corrosion agent.
w
A suitable polishing kit can be ordered from authorized dealers for treating rust spots.
11. Maintenance and service
116
5902916 MDS 8.2/14.2/18.2/20.2

Table of Contents

Other manuals for Rauch MDS 8.2