Case 2: Pin can be inserted into the metering opening and has more than 1 mm of play.
A new setting is required.
Remove pin from the metering opening.
Continue with chapter 11.5.1 Adjustment.
Case 3: Pin cannot be inserted into the metering opening.
A new setting is required.
Remove pin from the metering opening.
Continue with 11.5.1 Adjustment.
11.5.1 Adjustment
u
Start the tractor/unit/transformer.
u
Versions K/D/C
Close the metering slide.
Set the stop to the maximally open position (end of the slotted hole).
u
Open the metering slide to the stop.
Version K: The spring is now released.
u
Switch the tractor off and remove the ignition key or switch the unit / transformer off.
11. Maintenance and service
MDS 8.2/14.2/18.2/20.2 5902916
119

Table of Contents

Other manuals for Rauch MDS 8.2