EasyManua.ls Logo

Rauch MDS 8.2 - Page 110

Rauch MDS 8.2
150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault Possible cause Measure
Metering openings clogged by:
Fertilizer clumps
Moist fertilizer
Other impurities (leaves,
straw, bag residues)
Blockages
u
Park tractor, remove ignition
key, disconnect the power
supply,
u
Open metering slides.
u
Place the collecting vessel
underneath.
u
Remove spreading discs.
u
Clean the outlet from below
with a wooden pole or the
adjustment lever and push
through the metering
opening.
u
Remove foreign bodies from
the hopper.
u
Install spreading discs, close
metering slides.
10. Faults and possible causes
110
5902916 MDS 8.2/14.2/18.2/20.2

Table of Contents

Other manuals for Rauch MDS 8.2

Related product manuals