Fine adjustment (numeric scale)
u
Loosen the adjustment nut for the numeric scale using the adjustment lever of the machine.
u
Move the guiding plate to the number value specified in the calibration chart.
The specified number value is precisely aligned with the first guiding plate.
u
Tighten the adjustment nut for the numeric scale using the adjustment lever of the machine.
The unit is now set.
Fig. 56: Configuration table for the boundary spreading unit
[- -] Full border spreading is not possible
This working width cannot be reached
n
Correcting the spreading width
The values in the calibration chart are standard values. If there are differences in the fertilizer quality, it
may be necessary to correct the setting.
If only minor deviations occur, it is generally sufficient to modify the guiding plate setting.
To decrease the spreading distance relative to the calibration chart setting: Change the position
of the guiding plate on the numeric scale in the direction of the lower value.
To increase the spreading distance relative to the calibration chart setting: Change th position of
the guiding plate on the numeric scale in the direction of the higher value.
If there are greater deviations, move the TELIMAT housing along the alphabetic scale.
To decrease the spreading distance relative to the calibration chart setting: Change the position
of the housing on the alphabetic scale in the direction of the lower character (in alphabetical
order).
To increase the spreading distance relative to the calibration chart setting: Change the position of
the housing on the alphabetic scale in the direction of the higher character (in alphabetical
order).