Use and maintenance manual Touch Radio Hydro
Pag.46
Rev.0 18/05/2021
EN
Cleaning the turbulators
During operation, dust and soot are deposited on the surface of the heat exchanger tubes. To ensure smooth operation throughout
the season, it is advisable to periodically clean the heat exchanger when the stove is cold.
step action
1 Firmly move the turbulators up and down.
2 Once you have finished cleaning the exchanger, never leave the scraper removed.
Combustion chamber cleaning
To clean the ash drawer, proceed as follows:
step action
1
The stove requires a simple yet frequent cleaning in order to guarantee suitable yield and regular operation. Vacuum the
combustion chamber every day using a bin ash vacuum, making sure that the ashes are completely cold.
Cleaning the pellet tank
To clean the pellet tank, proceed as follows:
step action
1 Periodically remove the wood sawdust accumulated on the bottom of the tank, using a vacuum cleaner.
Extraction duct cleaning
Periodically check that the extraction duct is free from obstructions (dust, animal hair ...) and remove them if necessary.
In stoves with RDS technology, it is necessary to be extremely careful not to break the air flow sensor.
Extraordinary maintenance
Extraordinary maintenance activities must be carried out by staff from the Authorised Assistance Centre.
Do not wait for components to be deteriorated by use before proceeding with their replacement. Replace a worn component
before it is completely broken to prevent any damage caused by sudden component breakage.
PARTS/FREQUENCY 1 SEASON
Deep combustion chamber cleaning
Door gasket
Chimney
Smoke conduit
📌Schedule the above extraordinary maintenance activities with the Authorised Assistance Centre.