Raycus RFL-C30000M-CE - Pre-Installation Cleaning Instructions for Output Cables

Raycus RFL-C30000M-CE
65 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15
Figure5 Schematic diagram of the protective end cap of the optical cable
3.3.2 Pre-installation Cleaning Instructions for Output Cables
A) Preparation tools
Cleaning agent: absolute ethanol, or isopropyl alcohol.
Cleaning tools: cleaning cotton swabs, dust-free paper, compressed air bottles, etc.
B) Steps
a) Clean workbench should be turned on for at least 5 minutes, and the output optical cable should
be taken out of the black packaging box, as Figure 6. The outer surface of the shell shall be blown with
compressed air bottle for preliminary cleaning.
Figure 6 Output cable placed in the box
b) Place the output optical cable in a clean workbench;
Note: The following operations need to be carried out in a clean workbench. If the
operation is not carried out in a clean environment, it will cause great risk to the output optical
cable; operators need to wear finger cots to operate.