8 XP1-A1is high level, XP1-A6 is high level;
9 XP1-A1is high level, XP1-A3 is low level or suspending;
10 XP1-A1 is high level, XP1-A8~A14 is not all low level;
11 Emit laser: Send "EMON" by communication, or clickbutton of Emission “ON” on the PC
software
Turn off the laser: Send "EMOFF" by communication, or clickbutton of Emission “OFF” on the PC
software;
12 Emit red light: Send "ABN" by communication, or click button Guide laser “ON” on the PC
software
Turn off red light: Send "ABF" by communication, or click button of Guide laser “OFF” on the PC
software;
13 The communication sends "SDC XX" to set the power percentage, XX represents the power
percentage, or click button Power\Duty cycle\Frequency\Pulse width and then click the button of Set
on the PC software.
5.1 ON Mode
In the On mode, the user can send commands to set different working mode through PC
software or direct communication. After the laser is powered on again, the mode before power failure
will be memorized.AD Enable Mode
When AD mode is enabled, the laser power is determined by the analog voltage of pin 1 and pin
2 of XP4. If the AD mode is not enabled, the laser power can be set through the PC software or send
the “SDC XX” command.
5.3 Emission External Control Enable
When the emission external control is enabled, the laser emission is determined by the level
difference between the pins of MOD+ and MOD- in the XP2 port; if the emission external control is
not enabled, the laser emission or shutdown are determined by the emit button on the PC software.
Also, you can send “EMON” command to turn laser emission on, and send “EMOFF” command to
turn laser emission off.
5.4 Guide Laser (Red Guide Beam) Control
In “ON” mode guide laser can only be turned on/off by using PC software, or by sending
command of “ABN” (on) / “ABF” (off).
The red light module inside the laser works through communication, so there is a time delay of
at least 10ms for the opening and closing of red light
;