EasyManua.ls Logo

Raycus RFL-C30000M-CE - Page 63

Raycus RFL-C30000M-CE
65 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
62
2
SPT
0~65000(ms)
0~65000(W)
takes time for
parameter 1 to
change power
3
SPR
0~65000(W/ms)
0~65000(W)
Change the
power to
parameter 2 at
4
WAIT
1
WAIT 1 waiting
for synchronization
signal low level
/
2
Wait for
synchronization
/
3
Waiting for the
rising edge of the
synchronization
/
4
Wait for the
synchronization
signal to fall along
the space
/
5
Waiting time
0~65000ms(int)
5
GOTO
0~99
line
-1
When the
synchronization
signal is low
the jump
condition is met,
and the jump is
0~99
line
-2
Jump when sync
signal is high
Jump to other line
numbers when
conditions are
met
0~99
line
0~1000000
Number of times to
jump to this
line number
Number of times to
cycle to this
line number
续表 16
6
OUT
1
SO
1
Output
synchronization
2
Output
synchronization
7
EXT
Power
1
0~10V
2

Table of Contents