Ellipse INSTALLATION GUIDELINES
70-00159-01-09 Proprietary Redline Communications © 2015 Page 31 of 52 April 29, 2015
4.1.2 Step 2: Materials Supplied by Installer
Installation of the Ellipse System equipment requires additional equipment and materials
supplied by the installer. The following list is a guideline only, and additional materials
may be required based on local conditions at each installation site.
Table 12: Installation: Installer Supplied Materials
1
Cabinet or
Rack Space
The equipment cabinet must be rated for adequate protection against
ingress of water, dust, etc. and accommodate the size and heating/cooling
requirements of the system.
Mounting space allocated for the PoE power adapter. Must accommodate
2 m (6') AC power cable or DC power cables a required and routing of
Ethernet cable from PoE to local Ethernet network access point.
The following features are required:
- Ground block for grounding equipment, shielding on conductive cables,
and lightning protection devices
- DIN mounting rail with adequate spacing for equipment
- Weatherproof port glands for the Ethernet and power cables
- Security locking device to restrict access
- Fused sector controller blocks and surge protection for power input
2
Cabinet
Mast*
The cabinet mast must be rated for weight and wind loading of the
equipment cabinet and wiring. The mast must be adequately grounded.
3
Antenna
Mast*
The antenna mast must be rated for weight and wind loading of the Ellipse
sector controller. The mast must be adequately grounded.
4
Ethernet
Jumper
Cable
A short CAT-5e RJ-45 jumper cable is required to connect from the PoE to
the surge arrestor device at the ingress point of the cabinet. Typical length
610 mm (2 ft).
5
Power
The installer must provide 10-60 VDC or 120/240 VAC power to the
cabinet (based on site requirements). The DC-DC PoE power injector
sector controller block accepts 12-22 AWG wire.
6
Cable
Installation
Materials
Materials for securing cables to the masts, protecting cables from
abrasion, etc. including suggested weatherproofing materials:
Scotch 2200 series of vinyl mastic rolls
Scotch 130C linerless rubber splicing tape
3M Scotch super 88 electrical tape
7
System
Grounding
The site installation must include a master grounding system to be used
with all equipment. The wire gage must meet recommended industry
standards and include eye sector controllers for secure connection to
system equipment.
8
Tools
i) Precision set of screwdrivers, cutter pliers, and other common
installation tools.
ii) Portable computer for initial Ellipse System configuration.
iii) A CAT-5e RJ-45 jumper cable to connect the Ellipse to the PC.
* Note: cabinet and Ellipse system may be mounted on the same mast (based on site
survey results).
4.1.3 Step 3: Review Site Survey
Review the Site Survey section of this manual to verify that all installation requirements
are complete and all installation materials are available