Ellipse INSTALLATION GUIDELINES
70-00159-01-09 Proprietary Redline Communications © 2015 Page 38 of 52 April 29, 2015
Figure 24: Installation: Ethernet Port Gland Assembly
Use the following steps to connect the Ethernet cable. The connector assembly is
provided as a separate item in the shipping container.
1. Remove the connector from the packaging and arrange the individual components in
the order displayed in the diagram.
2. Insert the Ethernet cable through the sealing nut (4), seal (3), body (2) and gasket
(1).
3. Connect the Ethernet cable connector to the RJ-45 socket. Inserting the RJ-45 plug
into the socket should produce an audible 'click' from the locking mechanism.
4. Position the gasket (1) against the Ethernet port.
5. Thread the body (2) onto the Ethernet port. The body must be finger-tight plus 1/2
turn, or approximately 47 N-m (35 ft-lb).
6. Two sizes of split seals (3) are provided to accommodate single and double shielded
cables. Choose the seal that fits tightly on the cable without distorting. Slide the split
seal along the Ethernet cable until it is tight against the body (2).
7. Thread the sealing nut (4) on to the body. The sealing nut must be finger-tight plus
1/2 turn. This is approximately 47 N-m (35 ft-lb).

Table of Contents

Other manuals for Redline Communications RDL-3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Redline Communications RDL-3000 and is the answer not in the manual?

Redline Communications RDL-3000 Specifications

General IconGeneral
BrandRedline Communications
ModelRDL-3000
CategoryController
LanguageEnglish