17
For a description of this feature, see the figure in
“Scatter tolerance checking” on page 23.
Default: 3
RENC[27] Rapid traverse feedrate.
Default: 5000 mm/min
RENC[28] Select language.
1 = English, 2 = German, 3 = French, 4 = Italian
RENT[5] Number of the digital input for monitoring the probe
status signal. This can be used only if the machine tool
builder (MTB) has provided the input.
From Siemens 840D version 4 software or 810D
version 2 software, a Probe Status flag is available.
This is used as the default.
Default: 0 (Siemens Probe Status flag)
RENT[7] Measuring input used on I/O interface connector X121.
RENT[7] = 1 Configured for N/O input on MEPUS 0
RENT[7] = -1 Configured for N/C input on MEPUS 0
RENT[7] = 2 Configured for N/O input on MEPUS 1
RENT[7] = -2 Configured for N/C input on MEPUS 1
RENT[9] Tool management system in use.
RENT[9] = n, where ‘n’ is the location number, usually
1, in the tool buffer. This is decided by the MTB during
machine commissioning.
Default: 0 (i.e. disabled)
Setting-data subroutine