87
Message FORMAT ERROR
Meaning A subroutine input is either missing or the value entered
is incorrect.
Action Correct the subroutine input line then run again.
This is a reset condition.
Message ACTIVE BEAM CUT
Meaning The receiver is registering a cut beam signal at the start
of a measuring move. This may be due to the tool, swarf
or coolant interfering with the beam.
Action Correct the error then try again.
This is a reset condition.
Message BEAM NOT CUT
Meaning The receiver has not registered a beam cut condition
during the measuring move, possibly because the tool is
missing or the measuring distance is insufficient to reach
the beam. This may be due to bad subroutine input data
or failure to properly calibrate the probe system.
Action Correct the error then try again.
This is a reset condition.
Message RPM OUT OF RANGE <800
Meaning The value entered in the R19=s input is less than the
minimum value of 800 rev/min.
Action Correct the subroutine input line then run the subroutine
again.
This is a reset condition.