19
RENC[19]=3150; DEFAULT RPM
RENC[21]=1; BEAM AXIS
RENC[22]=2; RADIAL MEASURE AXIS
RENC[23]=3; SPINDLE AXIS
RENC[24]=.01; SCATTER TOL (0.0004 in)
RENC[25]=.025; RUN OUT/CUTTING-EDGE TOL (0.001 in)
RENC[26]=1; SAMPLE SCATTER SIZE
RENC[27]=5000; RAPID TRAVERSE
RENC[28]=1; LANGUAGE 1=GB 2=D 3=FR 4=IT
RENT[5]=0;DIGITAL INPUT NO
RENT[7]=1;MEASURE INPUT
RENT[9]=0;MAGAZINE NUMBER FOR TL MANAGEMENT
RENT[28]= ;DISABLE LATCH
RENT[29]= ;ENABLE LATCH
LN2:
Common parameters
The following parameters are loaded automatically each time a cycle
is run.
RENC[16] Active tool length.
RENC[29]
to Used for internal calculations
RENC[47]
RENC[48] Tolerance flag output
(1 = Out of tolerance, 0 = In tolerance)
RENC[49] Used for internal calculations
Setting-data subroutine